The R&S ZNH is a full two-port handheld vector network analyzer (VNA) that offers one-port cable and antenna measurement and full two-port S-parameter measurements. The touch-based interface simplifies operation and a configuration overview menu makes measurement preparation more efficient. The R&S ZNH may have a small form factor, but it is complete in every detail and delivers good performance and all the key functionalities.
Maintaining the operation of RF communications systems requires fast identification of any defects in the system components. The R&S ZNH, a multifaceted handheld vector network analyzer, helps on-site field engineers remedy defective components detected in the system. The basic version of the R&S ZNH handheld VNA can perform one-port cable and antenna measurements and four S-parameter measurements. With the addition of an optional power meter, pulse measurement, wave ratio, and wave quantities functionalities, the R&S ZNH enables field engineers to maintain and restore radar and satellite systems swiftly.
The ZNH basic unit includes:
There are also several optional measurement modes. More information on these can be seen further below. The part numbers are indicated in parentheses.
The ZNH is available in four models, with maximum frequencies ranging from 4 to 26.5 GHz. The following is a brief overview of the main features of each.
Model | Catalog | Maximum frequency | Number of ports | CAT functionality | S-parameter | RF Connector |
ZNH4 | 1321.1611.04 | 4 GHz | 2 | Standard | Standard | N |
ZNH8 | 1321.1611.08 | 8 GHz | 2 | Standard | Standard | N |
ZNH18 | 1321.1611.18 | 18 GHz | 2 | Standard | Standard | N |
ZNH26 | 1321.1611.26 | 26.5 GHz | 2 | Standard | Standard | PC 3.5mm |
The four-receiver architecture consists of dedicated reference receivers and test receivers at both port 1 and port 2. This allows the ZNH to support more advanced calibration types such as unknown through, open, short, and match (UOSM) calibration. This calibration is useful for DUTs with different input or output connector types at the test ports.
The multi-touch screen offers the standard pinch to zoom function available on smartphones. The ZNH supports typical phone control gestures, helping users feel at home. Even if operators cannot access the instrument directly, free PC, Android, and iOS remote control apps are available for seamless operation. Furthermore, the measurement wizard helps simplify measurements with automated test sequences, speeding up the test process and reducing the potential for human error.
With 16001 points per trace, the R&S ZNH can measure electrically long cables with no limitations. This enables the detection of cable discontinuities, which is important for base station antenna installation. For the one-port cable loss measurement, only one end of the cable needs to be connected to the R&S®ZNH test port; the other end can be terminated with a short circuit or left open.
Alternately, the antenna system performance can be assessed with reflection measurements. When a minimum amount of the transmitted signal is reflected, it indicates that the transmission energy efficiently covers the intended area. Unnecessarily high reflection makes the system inefficient and can damage components. Reflection measurements can be expressed in terms of return loss, VSWR, and the reflection coefficient.
S-parameters are the basic measured quantities of a network analyzer. They describe how the DUT modifies a signal that is transmitted or reflected in the forward or reverse direction. During product development and manufacturing, it is common to test component specifications and verify design simulations to ensure systems and their components work properly. In the field, S-parameter measurement helps to verify and troubleshoot deployed RF and microwave systems. The full two-port R&S ZNH offers the four S-parameter (S11, S21, S12, S22) measurements as standard. The VNA features single, split, triple, and quad display modes and various formats.
Any high-precision power measurement application, for instance, level calibration, requires very high accuracy to measure and align transmitting power. When equipped with the R&S NRPxx power sensors and the ZNH-K9 option, the R&S ZNH becomes an accurate RF power meter with a wide measurement range. Calibration is not required prior to making measurements since the sensors are fully characterized over frequency, level, and temperature and feature long-term stability. Zeroing is usually not required; the user can plug in a sensor and simply start measuring.
The ZNH-K29 option enables precise pulse and peak power measurements using the ZNH together with a Rohde & Schwarz wideband power sensor. Field applications benefit from this compact, powerful combination.
During installation and maintenance of radar systems, pulse characteristics and output power have to be measured. Due to a maximum video bandwidth of 30 MHz and a rise/fall time of < 13 ns, the sensors can measure pulses with a pulse width as short as 50 ns.
When installing and maintaining even the latest generation of microwave link modules, the user benefits from the sensor's high measurement speed and wide dynamic range.
Automatic pulse analysis helps the user measure important pulse parameters. This analysis eliminates the need for complex measurements using markers. Changes in the pulse shape are immediately taken into account in the measurement results.
The following parameters are determined by automatic pulse analysis:
Certain systems, such as tower-mounted amplifiers (TMA) for mobile communications applications, require DC power to be fed via the RF cable. Standard setups consist of a handheld analyzer, a 110V/230V plug-in power supply, a dedicated bias tee, and cables. The R&S ZNH has an integrated bias tee that does not require these components as additional external devices and can be battery-operated. The VNA acts as a hassle-free variable voltage source to provide the power these systems need for testing, installation, and maintenance.
The R&S ZNH-K45 vector voltmeter option displays the magnitude and phase of a DUT at a fixed frequency. The ZNH can therefore replace a conventional vector voltmeter for many applications. The required signal source and bridge are already available in the ZNH.
The setup is extremely simple, which makes the R&S ZNH-K45 ideal for field use. The results of relative measurements from a reference DUT can be stored at the push of a button. Comparison measurements, e.g. between various RF cables and a reference cable (golden device), can be quickly and easily performed. Typical applications are:
R&S ZNH offers four fully coherent receivers/channels. This means there are two additional sets of measurement parameters, which have an unambiguous meaning even if the DUT is measured outside its linear range:
The wave quantities provide the absolute power and phase at the various receivers of the analyzer ports. Wave quantities are therefore suitable for the following measurement tasks:
Overview of Handheld Analyzers | |||||||
Applications | Customers | Measurements / functions required | Measurements/functions available in | ||||
ZPH | ZVH | ZNH | FPH | FSH | |||
Installation & maintenance | • Communication, mobile and broadcast operators and contractors • Satellite and radar system integrators, contractors, end- users (civil and military) |
Antenna performance | ✓ | K39 | ✓ | - | K42** |
Cable performance | ✓ | K39 | ✓ | - | K42** | ||
Cable fault identification | ✓ | ✓ | ✓ | - | K41** | ||
Waveguide fault identification | - | K41 | - | - | ✓ | ||
Filter performance | ✓* | K39 | ✓ | - | K41** | ||
RF transmission / spectrum analysis | K1** | K1 | - | ✓ | ✓ | ||
Power measurement with power sensor |
K9 | ✓ | |||||
AM/FM transmission [Radio broadcaster] |
K7* | - | - | K7 | - | ||
Pulse measurement [Radar customer] |
K29 | ||||||
EMF measurement (with TS-EMF antenna) |
✓*** | ✓*** | - | ✓*** | K105 | ||
LTE demodulation measurement | - | - | - | - | K50/ K50E/ K51/ K51E | ||
GPS information – Built-in GPS receiver External GPS receiver |
B10* | - | |||||
HA-Z240 (ZVH & FSH) / HA-Z340 (the rest) | |||||||
Interference hunting | • Mobile and broadcast operators and contractors • Satellite and radar system integrators, contractors, end- users (civil and military) • Regulators |
Spectrogram (recording) | K15** | K14 | - | K15 | K15 |
Triangulations (with HE400 antenna) |
K15** | - | - | K15 | K15 | ||
Indoor/outdoor mapping | K16** | - | - | K16 | K17 | ||
Geotagging/ Signal strength mapping | K16** | - | - | K16 | K16 | ||
Spectrum and EMF measurement | Spectrum analysis - OBW, channel power and SEM, etc |
K1** | K1 | - | ✓ | ✓ | |
EiRP measurement | - | - | - | ✓ | - | ||
EMF measurement (with TS-EMF antenna) |
✓*** | ✓*** | - | ✓*** | K105 | ||
R&D measurement | EMI debugging (with HZ-15/17 probes) |
- | - | - | K43 | K43 | |
Components testing (DUT dependent) |
✓* | K39 / K42 | ✓ | - | ✓** | ||
Education | RF transmission / Spectrum analysis | K1** | K1 | - | - | ✓ | |
Production testing | AM/FM transmission | K7* | - | - | K7 | - | |
Pulse measurement | K29 | ||||||
Go/No-go testing (limit line) | ✓ | ✓ | ✓ | ✓ | ✓ | ||
*For ZPH - S11 and S21 only, FSH (.23/.30) – S12 and S22 only **Models dependent (pls check the respective analyzer datasheet) ***Basic field strength measurement (no demodulation & reporting) |
Network analysis | ||
Frequency range | 30 kHz to 26.5 GHz | |
Test port connector | 3.5 mm, male | |
Number of test ports | 2 | |
Standard measurement functions | one-port cable and antenna measurement | reflection and transmission measurement, one-port cable loss, DTF measurement |
two-port vector network analysis | S11, S21, S12, S22 | |
Result format | ► dB magnitude ► phase ► unwrapped phase ► Smith ► linear magnitude ► real ► imaginary ► SWR ► polar ► group delay |
|
Calibration methods | ► reflection normalization (open and short) ► reflection (OSM) ► transmission normalization (P1 and P2) ► transmission normalization in both directions ► TOSM ► UOSM |
|
Dynamic range | 100 dB (typ.) | |
Output power | 0 dBm (typ.) | |
Trace noise magnitude (RMS) | 0.0015 dB (typ.) | |
Trace noise phase (RMS) | 0.0015° (typ.) | |
Measurement speed | 761 µs per point | |
Number of measurement points | selectable | 3 to 16001 |
Measurement bandwidth | range | 10 Hz to 100 kHz in 1/3/10 steps |
Measurement range | –120 dB to +30 dB | |
Maximum rated input leve | CW RF power | 23 dBm (= 0.2 W) |
peak RF power | 26 dBm (= 0.4 W) | |
DC bias output voltage | mode: internal | +2 V to +32 V in 0.1 V steps (nom.) |
General data | ||
Display size | capacitive touchscreen | 7" |
Display resolution | WVGA | 800 x 480 pixel |
Battery (R&S®HA-Z306) | capacity | 72 Wh (version E), 74.5 Wh (version F and above) |
voltage | 11.25 V (nom., version E) 10.8 V (nom., version F and above) | |
Operating time with new, fully charged battery | 4 h | |
Dimensions | W x H x D | 202 mm × 294 mm × 76 mm (8.0 in × 11.6 in × 3 in) |
Weight | 3.1 kg (6.8 lb) |
Spectrum Analyzers/Spectrum Analyzers Template |
|
---|---|
Bandwidth Range Max | 26.5 GHz |
Bandwidth Range Min | 30 kHz |
Type(Spectrum Analyzers) | Handheld |
Test Equipment General Attributes |
|
HTS/Schedule B Number | 9030840000 |
ECCN Number | 3A992 |
Country of Origin | Malaysia |
We appreciate your business and are committed to providing you with exceptional service and timely delivery. Please review the shipping information below for your order.
Order Processing Time:
Orders are usually processed within 24-48 hours after the order has been placed.
Custom or special order items may take longer to process, typically 3-5 business days.
Shipping Methods:
Standard Shipping (3-7 business days)
Expedited Shipping (2-3 business days)
Express Shipping (1-2 business days)
Packaging:
Rest assured that all items will be securely and safely packaged to prevent any damage during transit. Fragile or high-value parts will be packaged with additional protective materials, such as bubble wrap or foam padding.
Shipping Rates:
Shipping rates vary based on the size, weight, and destination of the package. You can view the estimated shipping costs for your order during the checkout process before placing your order.
Order Tracking:
Once your order has been shipped, you will receive an email with the tracking number and carrier information. You can also track your order status by logging into your account.
International Shipping:
We ship worldwide! Please note that international shipping rates and delivery times may vary based on destination. Customers are responsible for any customs fees, import taxes, or additional charges that may apply.